Condensation constant climate test according to DIN EN ISO 6270-2
These tests can be used to determine how the test specimens behave in humid climates and to identify any defects in the corrosion protection.
ISO 6270 specifies the general conditions and procedures to be followed when exposing coated test specimens to condensation in a constant or alternating climate.
sample preparation | As agreed |
test chamber | Liebisch KSW 300 |
test conditions | (40±3)°C; 100% relative humidity with condensation on the sample surface |
test duration | As agreed |
sample evaluation | As agreed |
Example applications for condensation water constant climate tests
Constant climate tests for technical safety and aluminum surfaces
Coating materials are tested for their resistance to moisture (condensation). The stress is tested in condensation water constant climates or condensation water alternating climates.
Find out more about our expertise in the field of technical safety or in the field of aluminum surfaces
You can find an overview of other methods in the field of environmental simulation in our Lexicon – Environmental simulation