Neutral salt spray test according to DIN EN ISO 9227
Assessment of the susceptibility to corrosion of a metallic material, with or without corrosion protection, in relation to a neutral sodium chloride solution.
sample preparation | As agreed |
test chamber | Erichsen 606/1000 |
test temperature | (35±2)°C |
inspection solution | Neutral (5±0.5)% NaCl solution with a pH of 6.5–7.2. |
test duration | As agreed |
sample evaluation | As agreed, e.g.
|
Example applications for salt spray tests
Salt spray tests for surfaces
Salt spray tests are frequently used in the field of surfaces to test coatings. Such a test can be carried out, for example, to determine or compare the adhesion of a coating. To do this, samples are visually assessed at defined time periods and, for example, pitting corrosion or crevice corrosion is recorded and documented.
Find out more about our expertise in the field of aluminum surfaces
Salt spray tests for technical safety
The safety of components depends to a large extent on their area of application. That is why test specimens are exposed to corrosive media in time-lapse tests to provoke corrosion attacks. In particular, metallic components that are exposed to the environment should be tested with salt spray tests as part of technical safety.
Find out more about our expertise in the field of technical safety
You can find an overview of other methods in the field of environmental simulation in our encyclopedia – environmental simulation.